AC DC converter-swicthing power module test method,below has some few factors to get the point.
1. aim
Set the moduel testing princeple and the test method
2. test equipment and instrument
Ac power, digital multimeter, oscilloscope, the signal source, test equipment, and insulation resistance etc…
3. test princeple chart
test princeple chart as chart 5
3. test princeple chart
test princeple chart as chart 5
4. electrical parameter
Output voltage V
Module in the inpout rating voltage, full load output, testing the output ports value VO with multimeter, VO shoule meet the chart 1 regulation
Max output current Iomax
Module in the input rating voltage, full load output, in series load return circuits multimeter shall be the output current, or with other method (eg: resistance sampling test )
Vp-p output ripple voltage Vp-p
Module in input rating voltage, full load output, with an oscilloscope in provisions under the bandwidth to the shortest grounding method in the output measured theexcahnge peak voltage value that is Vp-p
Sv voltage adjust rate Sv
when full load output and output voltaVO,then:
ηefficiency η
Module with the fulling load output, input =Vi measuring the output voltage VO:
adjust the input voltage Vimax and Vimin, getting the output voltage Vomax、Vomin。
Si load adjust rate Si
Module in input rating voltage, 50% load output, output Voltage VOH;
Withstand voltage test
When output current full load IO, measure the output voltage VO,and the input voltage Vi, input current Ii, then:With voltage tester voltage is set to2000VAC,5mA in the input ( L, N short circuit) to perform measurement between the output (output footprints are all short circuit ), test time is 3 ± 1s; with voltage tester voltage is set to500VAC,5mA, shell on the output ( output footprints are all short circuit ), test time is 3 ± 1s;
Output voltage V
Module in the inpout rating voltage, full load output, testing the output ports value VO with multimeter, VO shoule meet the chart 1 regulation
Max output current Iomax
Module in the input rating voltage, full load output, in series load return circuits multimeter shall be the output current, or with other method (eg: resistance sampling test )
Vp-p output ripple voltage Vp-p
Module in input rating voltage, full load output, with an oscilloscope in provisions under the bandwidth to the shortest grounding method in the output measured theexcahnge peak voltage value that is Vp-p
Sv voltage adjust rate Sv
when full load output and output voltaVO,then:
ηefficiency η
Module with the fulling load output, input =Vi measuring the output voltage VO:
adjust the input voltage Vimax and Vimin, getting the output voltage Vomax、Vomin。
Si load adjust rate Si
Module in input rating voltage, 50% load output, output Voltage VOH;
Withstand voltage test
When output current full load IO, measure the output voltage VO,and the input voltage Vi, input current Ii, then:With voltage tester voltage is set to2000VAC,5mA in the input ( L, N short circuit) to perform measurement between the output (output footprints are all short circuit ), test time is 3 ± 1s; with voltage tester voltage is set to500VAC,5mA, shell on the output ( output footprints are all short circuit ), test time is 3 ± 1s;